We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Usage evaluation.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Usage evaluation - List of Manufacturers, Suppliers, Companies and Products

Usage evaluation Product List

1~2 item / All 2 items

Displayed results

Evaluation using PLAZMARK atmospheric pressure plasma <Verification of distribution>

Color measurement was conducted using the Konica Minolta automatic scanning spectrophotometer FD-9, and color difference mapping was performed!

Using the No. 41 (high sensitivity) for "atmospheric pressure plasma," we conducted a distribution evaluation of a long-type atmospheric pressure plasma device. As a result, visual inspection revealed detectable unevenness in the treatment by the atmospheric pressure plasma device. The center showed significant discoloration, indicating a bias in plasma treatment. Since we can understand the condition of the currently used device, it can also be utilized for maintenance purposes. Additionally, by using a color difference meter, numerical analysis can be performed, allowing for quantitative evaluation of the distribution within the area. 【Device Information】 ■ Device Model: AP-2000 manufactured by Denshi Giken Co., Ltd. Dielectric barrier discharge atmospheric pressure plasma device ■ Treatment Conditions: CDA: 6SLM, Output 7.5kV, Treatment Speed 300mm/min, Treatment Count 1 time ■ Color Difference Meter: Konica Minolta fluorescent spectrophotometer FD-9/MYIRO-9 (Measurement Light Source C, Illumination System C Light Source, 2° Field of View) *For more details, please refer to the related links or feel free to contact us.

  • Plasma surface treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Evaluation using atmospheric pressure plasma <Verification of correlation with contact angle>

The color difference ΔE*ab increases! Even weak plasma treatment effects can be detected by the indicator.

Using No. 41 (high sensitivity) and No. 42 (low sensitivity) of "PLAZMARK atmospheric pressure plasma," we will confirm the color change of the indicators before and after dry air atmospheric pressure plasma treatment, as well as the contact angle of water on PET film and the color difference of the indicators. The No. 41 (high sensitivity) indicator showed a correlation with the contact angle of water on PET film under weak plasma treatment conditions, while the No. 42 (low sensitivity) indicator also showed a correlation with the contact angle of water. For detailed technical data, please refer to the related links. 【Equipment Information】 ■ Equipment Model: AP-2000 manufactured by Denshi Giken Co., Ltd. Dielectric barrier discharge atmospheric pressure plasma device ■ Color Difference Meter: Fluorescent spectrophotometer manufactured by Konica Minolta, Inc. FD-5 (Measurement light source M1, illumination system C light source, 2° viewing angle) *For more details, please refer to the related links or feel free to contact us.

  • Plasma surface treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration